Victron Lynx Distribution 

The Victron Lynx Distributor System is a modular busbar system thatLYNX SET UP Victron Lynx Distributor incorporates DC connections, distribution, fusing, battery monitoring and/or Lithium battery management. For more information, see the DC Distribution Systems product page.

The Lynx Distributor System consist of the following parts:

  • Lynx Power In – A positive and negative busbar with four batteries or DC equipment connections, available in two versions, with M8 or M10 busbar.
  • Lynx Distributor – A positive and negative busbar with four fused connections for batteries or DC equipment and fuse monitoring, available in two versions, with M8 or M10 busbar. Thats the Victron Lynx Distributor
  • Lynx Shunt VE.Can – A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
  • Lynx Smart BMS – For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring. It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal. Available as a 500A model with M8 busbars or 1000A model with M10 busbars.
Read more

Victron Lynx Set Up

LYNX SET UP Victron Lynx Distributor

The Victron Lynx Range

Mega and CNN Fuse

Operation Lynx Distributor

When the Lynx Distributor is powered up by the Lynx Smart BMS, all LEDs will light up for one second. Afterward, the address briefly is shown via a fuse LED. Fuse 1 LED illuminates for Distributor A. Fuse 2 LED illuminates for Distributor B. The power LED is orange during power up and will turn green once power up is complete.

Normal operation

During normal operation the power LED is green, and all fuse LEDs are off. This means everything is all right. The bus is powered, and all fuses are okay.

Alarm operation

When a fuse blows (or is missing) the power LED turns red and the fuse LED of the affected fuse turns red.

When the busbar is not powered, the power LED turns yellow. This can occur, for example, when the main fuse in the Lynx Shunt VE.Can has blown. As a result, all downstream Lynx Distributors have unpowered busbars.

LED overview

The operational status of the Lynx Distributor is communicated via LEDs. This is the overview:

Table 2. Lynx Distributor LED overview
LED indicationStatus
Power LED yellow + fuse LEDs offNo voltage supplied to the positive bus bar
Power LED green + fuse LEDs offPositive bus bar is powered, and all fuses are ok
Power LED red + fuse led(s) redOne or more fuses are blown
All LEDs light up for one secondPowering up